Automotive Test Scope ATS610004D-XMSG

The USB labscope packed with technology

Price:  2,112.00

Key specifications

  • 14 bit (0.006 %) resolution (16 bit enhanced resolution)
  • Up to 1 GSa/s sampling
  • 250 MHz bandwidth
  • Up to 200 MSa/s continuous streaming
  • Up to 256 Mpoints memory per channel
  • 0.25 % DC vertical accuracy, 0.1 % typical
  • 1 ppm time base accuracy

Full specifications Manual Request info

Order code: ATS610004D-XMSG
EAN: 7423634563582
Price: 2,112.00

This powerful USB 3.0 super speed automotive oscilloscope combines fast sampling up to 1 GSa/s with high resolutions of 12, 14 and 16 bit and a large memory of 64 Mpoints on all four channels. Additionally, the automotive oscilloscope supports continuous streaming measurements up to 200 MSa/s.

The Automotive Test Scope ATS610004D-XMSG is delivered with SureConnect connection test and resistance measurement on each channel.

Also, the Automotive Test Scope ATS610004D-XMSG is delivered with SafeGround. With SafeGround you can switch the differential inputs of the Automotive Test Scope ATS610004D-XMSG into single ended inputs with ground protection. It allows to make measurements using standard attenuating probes and protects the scope when a short circuit to ground is created.

Safe measuring

The Automotive Test Scope ATS610004D-XMSG is a four channel automotive oscilloscope with differential inputs. With the differential inputs it is possible to measure four totally unrelated signals simultaneously. It is no longer possible to create a short circuit through the oscilloscope or through a second device connected to your computer and to the car, like e.g. a fault code scanner. So no risk of damaging the car, the oscilloscope or the computer.

Read differential input details

Diff input

Differential / single ended switchable inputs with SafeGround protection

SafeGround gives the possibility to use the oscilloscope inputs both as single ended and as differential. When SafeGround is active and you accidentally create a wrong connection that causes a short circuit, SafeGround will disconnect the ground of the input channel without damaging the oscilloscope or PC. You can therefore simply switch from a differential input to a single ended input without worrying if anything will damage because of a short circuit current. The Automotive Test Scope ATS610004D-XMSG is the only automotive oscilloscope in the world with this unique SafeGround protection. And as you all know, a connection mistake is easily made, which will now have no more strange and financial consequences because of SafeGround as the short circuit current is limited thanks to SafeGround.

SafeGround is default available on each channel of the Automotive Test Scope ATS610004D-XMSG.

Read SafeGround details

SafeGround

SureConnect

The SureConnect connection test feature of the Automotive Test Scope ATS610004D-XMSG tells you immediately whether your test probe or clip actually makes electrical contact or not. No more doubt whether your probe doesn't make contact or there really is no signal.

This is useful when surfaces are oxidized and your probe cannot get a good electrical contact. Simply activate the SureConnect and you know whether there is contact or not. Also when back probing connectors in confined places, SureConnect immediately shows whether the probes make contact or not.

SureConnect is default available on each channel of the Automotive Test Scope ATS610004D-XMSG.

Read SureConnect details

SafeGround

Resistance measurement

Many automotive sensors are based on variable resistors. Use your Automotive Test Scope ATS610004D-XMSG in the resistance setting to test them, no more need to take a separate ohm meter. Resistance values can be displayed as a number, but it is also possible to display the resistance variation in time, in a graph.

The unique Automotive Test Scope ATS610004D-XMSG Ohm scope is the first fast automotive Ohm scope in its class.

Read resistance measurement details

Potmeter testing

Large memory

When measuring at high sample rates, a long record length/large memory is necessary to be able to record a complete signal in the acquisition buffer. Where most oscilloscopes have 2.5 kpoints or 100 kpoints memory, the Automotive Test Scope ATS610004D-XMSG has up to 256 Mpoints memory per channel, depending on the selected resolution and the number of active channels. When measuring at 14 bit resolution and all four channels, the available memory is 32 Mpoints per channel. This gives the user 300 to 100000 times more memory.

An advantage of a large memory is that once-only fast phenomena can be captured accurately or complete serial communication signal blocks can be measured all at once. For example complete serial communications, like CAN bus signals, can be measured all in one record to be reviewed and analyzed afterwards.

Read large memory details

Zoom in 1 million times

High accuracy

The Automotive Test Scope ATS610004D-XMSG measures with high resolutions of 14 and 16 bit. A signal measured with the Automotive Test Scope ATS610004D-XMSG therefore has 256 times more resolution than most standard automotive oscilloscopes, which usually have a low resolution of 8 or 9 bit. The input circuit of the Automotive Test Scope ATS610004D-XMSG has a high accuracy of 0.25 % of the full scale input range, where most standard automotive oscilloscopes have an accuracy of 2 - 3 % of the full scale range. The precision Automotive Test Scope ATS610004D-XMSG allows for measuring signals with much more accuracy.

Read high accuracy details

Zoomed in to 8 mV range

Automotive Test Scope ATS610004D-XMSG specifications

The tables below show detailed specifications of the Automotive Test Scope ATS610004D-XMSG. Jump to specifications regarding

Acquisition system

Number of input channels4 analog
CH1, CH2, CH3, CH4Isolated BNC, female
TypeDifferential input
ResolutionUser selectable in software
Native8, 12, 14 bit
Enhanced16 bit
DC Accuracy0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Noise305 µVrms (200 mV range, 12 bit, 50 MSa/s)
90 µVrms (200 mV range, 16 bit, 6.25 MSa/s)
Ranges (full scale)±200 mV
±400 mV
±800 mV
±2 V
±4 V
±8 V
±20 V
±40 V
±80 V
CouplingAC/DC
Impedance2 MOhm / 12 pF ± 1 %
1 MOhm / 20 pF ± 1 % when SafeGround enabled
Maximum voltage200 V (DC + AC peak < 10 kHz)
Maximum Common Mode voltage200 mV to 800 mV ranges 2 V
2 V to 8 V ranges : 20 V
20 V to 80 V ranges : 200 V
Common Mode Rejection Ratio-47 dB
Bandwidth 
-3dB at 75 % of full scale input250 MHz
Limit, selectable per channelOff (250 MHz), 150 MHz, 100 MHz, 50 MHz
AC coupling cut off frequency (-3dB)±1.5 Hz
SureConnect 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Resistance measurement 
Ranges100 Ω
200 Ω
500 Ω
1 kΩ
2 kΩ
5 kΩ
10 kΩ
20 kΩ
50 kΩ
100 kΩ
200 kΩ
500 kΩ
1 MΩ
2 MΩ
Accuracy1 % of full scale
Response time (to 95%)< 10 µs
SafeGround 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Maximum switch off current500 mA
Response time< 100 ns
 
Maximum sampling rate8 bit12 bit14 bit16 bit
measuring one channel1 GSa/s500 MSa/s100 MSa/s6.25 MSa/s
measuring two channels500 MSa/s200 MSa/s100 MSa/s6.25 MSa/s
measuring three or four channels200 MSa/s100 MSa/s100 MSa/s6.25 MSa/s
 
Maximum streaming rate 18 bit12 bit14 bit16 bit 
measuring one channel200 MSa/s 2100 MSa/s 3100 MSa/s 36.25 MSa/s 6
measuring two channels100 MSa/s 350 MSa/s 450 MSa/s 46.25 MSa/s 6
measuring three or four channels50 MSa/s 425 MSa/s 525 MSa/s 56.25 MSa/s 6
  1. On some computers, the highest streaming rates may not be available, due to computer restrictions.
  2. ≤ 40 MSa/s when connected to USB 2.0
  3. ≤ 20 MSa/s when connected to USB 2.0
  4. ≤ 10 MSa/s when connected to USB 2.0
  5. ≤ 5 MSa/s when connected to USB 2.0
  6. ≤ 3.125 MSa/s when connected to USB 2.0
Sampling clock source 
InternalTCXO
Accuracy± 0.0001 %
Stability± 1 ppm over 0°C to 55°C
Time base aging±1 ppm/year
ExternalLVDS, on CMI connectors
Input range10 MHz ± 1 %
16.369 MHz ± 1 %
 
Memory8 bit12, 14, 16 bit
Measuring one channel256 Mpoints per channel128 Mpoints per channel
Measuring two channels128 Mpoints per channel64 Mpoints per channel
Measuring three or four channels64 Mpoints per channel32 Mpoints per channel
 
Trigger 
SystemDigital, 2 levels
SourceCH1, CH2, CH3, CH4, OR, digital external
Trigger modesRising edge, Falling edge, Any edge
Inside window, Outside window, Enter window, Exit window (time conditions only on Ch1)
Pulse width (only on Ch1)
Interval (only on Ch1)
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger0 to selected record length, 1 sample resolution
Post trigger0 to selected record length, 1 sample resolution
Trigger hold-off0 to 63 MSamples, 1 sample resolution
Trigger delay0 to 8 GSamples, 1 sample resolution
Digital external trigger 
InputExtension connector pins 1 and 2
Range0 to 2.5 V (TTL)
CouplingDC
Jitter≤ 1 sample

Multi-instrument synchronization

Using CMISynchronizing instruments via CMI is available when all instruments are connected via USB.
Maximum number of instrumentsLimited by number of available USB ports
Synchronization accuracy0 ppm
CMI interface2x, CMI 1, CMI 2
Required coupling cableTP-C50H Coupling cable CMI
Maximum coupling cable length50 cm
Using WCMISynchronizing instruments via WCMI is available when instruments are connected via USB, LAN and WiFi.
Maximum number of instrumentsNo limitation
Required coupling moduleWCMI - 8, WCMI - 9
Clock synchronization accuracy≤ 1 ppm, typical ≤ 0.2 ppm
Trigger jitter at sample rate 1≤ 1 MSa/s> 1 MSa/s
2 x "5"≤ ±2 samples≤ ±2 µs
"5" and "6" 
Trigger source "5"≤ ±2 samples≤ ±2 µs
Trigger source "6"≤ ±8 samples≤ ±8 µs
2 x "6"≤ ±8 samples≤ ±8 µs
  1. "5" = WiFiScope WS5 or Handyscope HS5.
    "6" = WiFiScope WS6 DIFF, WiFiScope WS6, Handyscope HS6 DIFF, Handyscope HS6, ATS610004DW-XMSG, ATS610004D-XMSG, ATS605004DW-XMS or ATS605004D-XMS

Probe calibration

OutputExtension connector pins 3 (signal) and 6 (ground)
SignalSquare wave
Level-1 V to 1 V
Frequency1 kHz

Interface

InterfaceUSB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)

Power Requirements

PowerFrom USB port or external input
Consumption5 VDC 1200 mA max
External powerFrom second USB port or power adapter

Physical

Instrument
Height25 mm (1 inch)
Length170 mm (6.7 inch)
Width140 mm (5.2 inch)
Weight500 g (17.6 ounce)
USB cord length1.8 m (70 inch)

I/O connectors

Channel 1, 2, 3, 4Isolated BNC, female
USBFixed cable with USB 3.0 type A connector, 1.8 m
Extension connectorD-sub 9 pins female
Power3.5 mm power socket
CMI I/O connectors2 x HDMI type C socket

System requirements

PC I/O connectionUSB 2.0, USB 3.0 or USB 3.1
Operating systemWindows 10 / 11, 64 bits
Linux (via own software based on libtiepie-hw SDK)

Environmental conditions

Operating 
Ambient temperature20°C to 25°C (10°C to 40°C without specifications)
Relative humidity10 % to 90 %, non condensing
Storage 
Ambient temperature-20°C to 70°C
Relative humidity5 % to 95 %, non condensing

Certifications and Compliances

CE mark complianceYes
RoHSYes
EN 55011:2009/A1:2010Yes
EN 55022:2006/A1:2007Yes
EN 61000-6-1:2007Yes
EN 61000-6-3:2007Yes

Package contents

InstrumentAutomotive Test Scope ATS610004D-XMSG
Measure leads4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator4 x Differential attenuator TP-DA10
AccessoriesHandyscope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30
Softwarefor Windows 10 / 11, via website
Driversfor Windows 10 / 11, via website
Manualsinstrument manual and software user's manuals
color printed and digital, via website

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for two years.
This warranty includesAll parts and labor (excluding probes and/or measure leads)
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge

The Automotive Test Scope ATS610004D-XMSG is delivered with:

Carry case Carry case BB391
Instrument Automotive Test Scope ATS610004D-XMSG
Measure leads 4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana plug
Differential attenuator 4 x Differential attenuator TP-DA10
Alligator clips, large Alligator Clip TP-AC80I - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 large alligator clips
Alligator clips, medium Alligator Clip TP-AC10I - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 medium alligator clips
Alligator clips, small Alligator Clip TP-AC5 - Set of 8: Green, Blue, Yellow, Red, 4 Black, 8 small alligator clips
Accessories Handyscope power supply, external power cable for USB port, Probe compensation cable TP-DB9-BNC-30
Software for Windows 10 / 11, via website
Drivers for Windows 10 / 11, via website
Manuals instrument manual and software user's manuals
color printed and digital, via website
Complete set

Several downloads for the Automotive Test Scope ATS610004D-XMSG are listed below, including Multi Channel oscilloscope software, drivers and manuals.

Driver & Software

DescriptionVersionRemarksSize
WinUSB driver10.0.2Windows 10 / 11, 64 bit1.73 MB download
Multi Channel software1.46.1Windows 10 / 11, 64 bit, including PDF manual100.56 MB download

Manuals & Documents

DescriptionVersionRemarksSize
Multi Channel software manual 1.08English2.90 MB download
Automotive Test Scope ATS610004D-XMSG Instrument manual2.44English953.88 kB download