Automotive scope ATS610004D-XMSG specifications

The tables below show detailed specifications of the Automotive scope ATS610004D-XMSG. Jump to acquisition specifications, trigger specifications or general specifications.

Acquisition system

Number of input channels4 analog
CH1, CH2, CH3, CH4Isolated male BNC
TypeDifferential input
Resolution8, 12, 14, 16 bit user selectable
DC Accuracy0.25 % (0.1 % typical) of full scale ± 1 LSB at 20°C to 25°C
To achieve rated accuracy, allow the instrument to settle for 20 minutes. When subjected to extreme temperatures, allow additional time for internal temperatures to stabilize.
Ranges±200 mV to ±80 V full scale
CouplingAC/DC
Impedance2 MOhm / 12 pF ± 1 %
1 MOhm / 20 pF ± 1 % when SafeGround enabled
Maximum voltage200 V (DC + AC peak < 10 kHz)
Maximum Common Mode voltage200 mV to 800 mV ranges 2 V
2 V to 8 V ranges : 20 V
20 V to 80 V ranges : 200 V
Common Mode Rejection Ratio-47 dB
Bandwidth 
-3dB at 75 % of full scale input250 MHz
Limit, selectable per channelOff (250 MHz), 150 MHz, 100 MHz, 50 MHz
AC coupling cut off frequency (-3dB)±1.5 Hz
SureConnect 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Resistance measurement 
Ranges100 Ohm to 2 MOhm full scale in 1-2-5 sequence
Accuracy1 % of full scale
Response time (to 95%)< 10 µs
SafeGround 
Maximum voltage on connection200 V (DC + AC peak < 10 kHz)
Maximum switch off current500 mA
Response time< 100 ns
 
Maximum sampling rate8 bit12 bit14 bit16 bit
measuring one channel1 GS/s500 MS/s100 MS/s6.25 MS/s
measuring two channels500 MS/s200 MS/s100 MS/s6.25 MS/s
measuring three or four channels200 MS/s100 MS/s100 MS/s6.25 MS/s
 
Maximum streaming rate 18 bit12 bit14 bit16 bit 
measuring one channel200 MS/s 2200 MS/s 3100 MS/s 36.25 MS/s 6
measuring two channels200 MS/s 3100 MS/s 450 MS/s 46.25 MS/s 6
measuring three or four channels100 MS/s 450 MS/s 525 MS/s 56.25 MS/s 6
  1. On some computers, the highest streaming rates may not be available, due to computer restrictions.
  2. ≤ 40 MS/s when connected to USB 2.0
  3. ≤ 20 MS/s when connected to USB 2.0
  4. ≤ 10 MS/s when connected to USB 2.0
  5. ≤ 5 MS/s when connected to USB 2.0
  6. ≤ 3.125 MS/s when connected to USB 2.0
Sampling clock source 
InternalTCXO
Accuracy± 0.0001 %
Stability± 1 ppm over 0°C to 55°C
Time base aging±1 ppm/year
ExternalLVDS, on CMI connectors
Input range10 MHz ± 1 %
16.369 MHz ± 1 %
 
Memory8 bit12, 14, 16 bit
Measuring one channel256 MS per channel128 MS per channel
Measuring two channels128 MS per channel64 MS per channel
Measuring three or four channels64 MS per channel32 MS per channel
 
Trigger 
SystemDigital, 2 levels
SourceCH1, CH2, CH3, CH4, OR, digital external
Trigger modesRising edge, falling edge, any edge, inside window, outside window, enter window, exit window, pulse width
Level adjustment0 to 100 % of full scale
Hysteresis adjustment0 to 100 % of full scale
Resolution0.006 % (14, 16 bits) / 0.025% (12 bits)
Pre trigger0 to selected record length, 1 sample resolution
Post trigger0 to selected record length, 1 sample resolution
Trigger hold-off0 to 63 MSamples, 1 sample resolution
Trigger delay0 to 8 GSamples, 1 sample resolution
Digital external trigger 
InputExtension connector pins 1 and 2
Range0 to 2.5 V (TTL)
CouplingDC
Jitter≤ 1 sample

Multi-instrument synchronization

Maximum number of instrumentsLimited by number of available USB ports
Synchronization accuracy0 ppm
CMI interface2x, CMI 1, CMI 2
Required coupling cableTP-C50H Coupling cable CMI
Maximum coupling cable length50 cm

Probe calibration

OutputExtension connector pins 3 (signal) and 6 (ground)
SignalSquare wave
Level-1 V to 1 V
Frequency1 kHz

Interface

InterfaceUSB 3.0 SuperSpeed (5 Gbit/s);
(USB 2.0 HighSpeed compatible)

Power Requirements

PowerFrom USB port or external input
Consumption5 VDC 1200 mA max
External powerFrom second USB port or power adapter

Physical

Instrument
Height25 mm (1 inch)
Length170 mm (6.7 inch)
Width140 mm (5.2 inch)
Weight500 g (17.6 ounce)
USB cord length1.8 m (70 inch)

I/O connectors

Channel 1, 2, 3, 4Isolated BNC
USBFixed cable with USB 3.0 type A connector, 1.8 m
Extension connectorD-sub 9 pins female
Power3.5 mm power socket
CMI I/O connectors2 x HDMI type C socket

System requirements

PC I/O connectionUSB 2.0, USB 3.0 or USB 3.1
Operating systemWindows 7/8/10, 32 and 64 bits
Linux (via LibTiePie SDK)

Environmental conditions

Operating 
Ambient temperature20°C to 25°C (10°C to 40°C without specifications)
Relative humidity10 % to 90 %, non condensing
Storage 
Ambient temperature-20°C to 70°C
Relative humidity5 % to 95 %, non condensing

Certifications and Compliances

CE mark complianceYes
RoHSYes
EN 55011:2009/A1:2010Yes
EN 55022:2006/A1:2007Yes
EN 61000-6-1:2007Yes
EN 61000-6-3:2007Yes

Package contents

InstrumentAutomotive scope ATS610004D-XMSG
Measure leads4 x Measure lead TP-C1812B, Differential BNC -> 4 mm banana jack
Differential attenuator4 x Differential attenuator TP-DA10
AccessoriesHandyscope power supply, external power cable for USB port
Softwarefor Windows 7/8/10 on CD
Driversfor Windows 7/8/10 on CD
Manualsinstrument manual and software user's manuals
color printed and digital on CD

Customer service

TiePie engineering instruments are designed, manufactured and tested to provide high reliability. In the unlikely event you experience difficulties, the TiePie engineering instruments are fully warranted for three years.
This warranty includesAll parts and labor (excluding probes)
No charge for return shipping
Long-term 7 year support
Upgrade to the latest software at no charge